Surveillance of alloantibodies after transplantation identifies the risk of chronic rejection

By 
Rate this item
(0 votes)

The monitoring of the levels of alloantibodies following transplantation might facilitate early diagnosis of chronic rejection (CR), the leading cause of renal allograft failure. Here, we used serial alloantibody surveillance to monitor patients with preoperative positive flow cytometric crossmatch (FCXM). Sixty-nine of 308 renal transplant patients in our center had preoperative positive FCXM. Blood was collected quarterly during the first postoperative year and tested by FCXM and single antigen bead luminometry, more sensitive techniques than complement-dependent cytotoxic crossmatching. Distinct post-transplant profiles emerged and were associated with different clinical outcomes.

Two-thirds of patients showed complete elimination of FCXM and solid-phase assay reactions within 1 year, had few adverse events, and a 95% 3-year graft survival. In contrast, the remaining third failed to eliminate flow FCXM or solid-phase reactions directed against HLA class I or II antibodies. The inferior graft survival (67%) with loss in this latter group was primarily due to CR. Thus, systematic assessment of longitudinal changes in alloantibody levels, either by FCXM or solid-phase assay, can help identify patients at greater risk of developing CR.

 

Authors: Pamela M Kimball, Melissa A Baker, Mary B Wagner and Anne King

Reference: Kidney International 79: 1131-1137; Published online, 26 January 2011; doi:10.1038/ki.2010.556

Additional Info

  • Language: English
  • Contains Audio: No
  • Content Type: Articles
  • Source: KI
  • Year: 2011
  • Members Only: No
Read 1702 times Last modified on Monday, 16 January 2017 07:47